Home What's New Products Company Support Contact Us
Search Index Help

Innerduct Pressure Test Kits

Innerduct Pressure Test Kit
Use the Innerduct Pressure Test Kit to pressure test the innerduct before setting up the Fiber Optic Cable Blower. The duct system must be able to withstand and hold 150 psi (10.3 bar) for the cable blower to work properly.
Innerduct Pressure Test Kit

Part Number
Description
08761457
Pressure Test Kit for 1", 1 1/4", & 1 1/2" SDR 11 & 13.5 Innerduct
• Control Valve Assembly
• Seal-Off Heads
• Pulling Eyes
• Pulling Grips
• Tool Box
Other Components Available
Part Number
Description
08034318
Seal-Off Head for 2.00" SDR 11 & 13.5 Innerduct
08913328
Pulling Eye for 2.00" SDR 11 & 13.5 Innerduct
08643155
Pulling Grip for 2.00" SDR 11 & 13.5 Innerduct

FAQ's

Accessories
   Condux Fiber Blower Tools and Replacement Parts
   Fiber Optic Cable Blower Cover 
   Micro Duct/Fiber Blower
   Hand Held Micro Fiber Blower 
   Innerduct Couplings
   Innerduct Pressure Test Kits       
   Cable Blowing Lubricants
   General Purpose Cleaner

Related Products

   Fiber Optic Cable Blowers   
   Compressed Air Cooler

Order Information

   Fiber Optic Cable Blowers
   Micro Duct/Fiber Blower
   Hand Held Micro Fiber Blower
   Compressed Air Cooler
   Winch Line Blower
   Winch Line Body & Adapters

Specifications
   Fiber Optic Cable Blowers
   Micro Duct/Fiber Blower
   Hand Held Micro Fiber Blower
   Winch Line Blower
   Winch Line Body & Adapters

Additional Information

   Why the Condux FO Blower is better
   FO Blowing Process
   FO Blower Cable and Duct Pack Reference Guide
   Why Lubricate

Mandrel and Pressure Test Kit
Use the Mandrel and Pressure Test Kit to pressure test 1 1/4" (32 mm) innerduct. The duct system must not be kinked or crushed and must be able to withstand and hold 150 psi (10.3 bar) for the cable blower to work properly.
Mandrel and Pressure Test Kit

 

Part Number
Description
08761495
Mandrel and Pressure Test Kit for 1 1/4" (32 mm) Innerduct
• Seal-Off Control Valve Assembly
• Pressure Test Control Valve Assembly
• 1 1/4" (32 mm) Innerduct Seal-Off Head
• Test Mandrel for 1 1/4" (32 mm) Innerduct
• Extra Rubber Discs for Test Mandrel
• Innerduct Pulling Eye for 1 1/4" (32 mm) Innerduct
• Cable Grip for over 1 1/4" (32 mm) Innerduct
• Tool Box
08761610
Test Mandrel for 1" (25 mm) Innerduct
08761237
Test Mandrel for 1 1/4" (32 mm) Innerduct
08761383
Test Mandrel for 1 1/2" (38 mm) Innerduct
08020610
Test Mandrel for 2" (51 mm) Innerduct

 

Why an Airtight Duct?
Duct integrity is essential for a successful cable blowing application. Leaks in the duct can lower pressure and greatly reduce installation distances. The duct system must be able to withstand and maintain 150 psi (10.3 bar) minimal leakage, the compressor will not be able to maintain pressure behind the cable carrier. This ultimately can reduce the pulling force of the cable carrier and can increase tractor drive pressure on the cable, resulting in increased cable stress.

Duct integrity should always be tested before attempting cable installation with the cable blower. The duct can be tested with a pressure test kit available from Condux or with the cable blower itself. Either way, an airtight duct system is an absolute necessity for cable blowing.

The main contributors to duct system leaks are the innerduct couplings. Condux recommends using one of the innerduct couplings that are posted with the Cable Blowing section in this website.