  • The digital display is not functioning.
    Turn the Electronic Control Box power switch ON, and check all electrical connections.

  • The digital display does not display expected values.
    If the LED light next to "N" is lit, the display is displaying the force in Newtons. Switch the display to pounds by turning the control box off, then press and hold the LIMIT RESET button while turning the power on. Hold the button down until the LED light next to the "lbs" on the dislay lights. Also, the rope size could be different from the size selected on the Electronic Control Box.

  • The numbers on the digital display start counting up and do not stop with no load on the rope.
    The load cell is not properly connected to the electronic control box. Make sure all connections are made and are tight.

  • The cable glider doesn't stop when the programmed tension limit is reached.
    1. The TENSION LIMIT CONTROL is OFF. Press the TENSION LIMIT CONTROL button ON (LED light is lit).
    OR
    2. The tension limit is not set to the desired load. Press and hold the SET TENSION LIMIT UP or DOWN buttons to set the desired value.
    OR
    3. Puller is not plugged into the elctroninc control box.

  • The cable puller stops before line tension reaches the preset load limit programmed into the Electroninc Contol Box.
    The tension limit is not set to the desired load. Press and hold the SET TENSION LIMIT UP or DOWN buttons to set the desired value.

  • Chart paper does not advance.
    Check the chart recorder cassette installation. Check the paper's alignment.

  • Chart recorder is not functioning.
    Remove the chart recorder from the Electronic Control Box (4 screws on face plate) and check pigtail connector for proper connection.

 